Aprilaire 800 Spezifikationen Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
DISPLAY PANEL
TABLE 4 – Display Panel
Icon Function
Main switch. Press to turn humidifier on and off.
Resets timer for start-up water conditioning.
Light
Solid green when humidifier is turned on.
Flashes green for one minute once power is restored if humidifier was operating when power was shut off.
Fill valve indicator.
Light
Solid green during normal operation when canister water is being replenished.
Flashes green (along with Drain light) indicating fill and drain valves are pulsing to dislodge mineral deposits.
Solid red if canister needs water but water is not detected. See Troubleshooting Guide.
Indicates call for humidity.
Light
Solid green during call for humidity.
Solid yellow if humidifier cannot reach nominal output within first 48 hours of operation due to insufficient water conductivity.
Humidifier will continue to cycle valves in an attempt to reach capacity for an additional 48 hours. Approximately 1/10
teaspoon of table salt can be added to fill cup to increase conductivity of water.
Drain valve indicator.
Light
Solid green to indicate start of drain cycle.
Drain cycle occurs:
1) To maintain nominal steam output during normal operation.
2) During end of season shut down. (End of season shut down occurs after 72 hours of inactivity.)
3) If humidifier has operated for 168 hours without a drain cycle.
4) When humidifier is turned off.
Flashes green (along with fill light) indicating drain and fill valves are pulsing to dislodge mineral deposits.
Flashes green when humidifier is turned off indicating canister is draining. When flashing stops, main power disconnect
can be turned off and front panel can be opened.
Indicates canister needs to be replaced or humidifier requires other type of service.
Light
Flashes red when canister can no longer supply demand and needs to be replaced because electrodes have been corroded
or coated with mineral deposits. Humidifier may continue to generate steam but at a reduced capacity.
Flashes red if humidifier with new canister cannot generate steam due to insufficient water conductivity after 96 hours of
drain/fill activity. Approximately 1/10 teaspoon of table salt can be added to fill cup to increase conductivity of water.
Solid red if controller detects over-current between electrodes. Causes may include electrodes coated with mineral
deposits, blocked drain, or defect in drain valve circuit. See Troubleshooting Guide.